EPD-IES-0029385:001

MyVallox 245 CFi

General information

EPD OwnerVallox Oy
Registration numberEPD-IES-0029385:001
EPD typeEPD of multiple products based on worst-case results
StatusValid
Version date2026-05-18
Validity date2031-05-18
Standards conformanceISO 14025:2006, EN 15804:2012+A2:2019/AC:2021
Geographical scopeEurope, Finland
An EPD may be updated or depublished if conditions change. This is the latest version of the EPD.

Programme information

ProgrammeInternational EPD System
AddressEPD International AB Box 210 60 SE-100 31 Stockholm Sweden
Websitewww.environdec.com
E-mailsupport@environdec.com

Product category rules

CEN standard EN 15804 serves as the Core Product Category Rules (PCR)
Product Category Rules (PCR)2019:14 Construction products (EN 15804+A2) (version 2.0.1) 2.0.1
PCR review was conducted byThe Technical Committee of the International EPD System. See www.environdec.com for a list of members. Review chair: Rob Rouwette (chair), Noa Meron (co-chair). The review panel may be contacted via the Secretariat www.environdec.com/support.
Complementary Product Category Rules (c-PCR)PCR 2019:14-c-PCR-018 Ventilation components (c-PCR under PCR 2019:14) (Adopted from EPD Norway) Version: Adopted from EPD Norway
c-PCR review was conducted byThe Technical Committee of the International EPD System

Verification

Independent third-party verification of the declaration and data, according to ISO 14025:2006, via
Third-party verifierValtteri Kainila (Ramboll Finland Oy)
Approved byThe International EPD® System
Procedure for follow-up of data during EPD validity involves third party verifier
*EPD Process Certification involves an accredited certification body certifying and periodically auditing the EPD process and conducting external and independent verification of EPDs that are regularly published. More information can be found in the General Programme Instructions on www.environdec.com.

Ownership and limitation on use of EPD

Limitations

EPDs within the same product category but published in different EPD programmes, may not be comparable. For two EPDs to be comparable, they shall be based on the same PCR (including the same first-digit version number) or be based on fully aligned PCRs or versions of PCRs; cover products with identical functions, technical performances and use (e.g. identical declared/functional units); have identical scope in terms of included life-cycle stages (unless the excluded life-cycle stage is demonstrated to be insignificant); apply identical impact assessment methods (including the same version of characterisation factors); and be valid at the time of comparison.

Ownership

The EPD Owner has the sole ownership, liability, and responsibility for the EPD.

Information about EPD Owner

EPD OwnerVallox Oy
Contact person nameSari Ponkala
Contact person e-mailsari.ponkala@vallox.com
Organisation addressMyllykyläntie 9-11 32200 Loimaa Finland
LCA PractitionerVeera Hursti, veera.hursti@comatec.fi aleksi.surakka@comatec.fi, aleksi.surakka@comatec.fi Leena Heikinmaa, leena.heikinmaa@comatec.fi

Description of the organisation of the EPD Owner

Vallox Oy is a Finnish company focused on designing and manufacturing ventilation products. For more than 50 years, it has been visionary in the development of indoor air technology, and today it serves customers widely across Europe. Vallox is on a mission to take care of wellbeing of people and maintaining the value of the homes with smart ventilation. High-quality and energy-efficient Vallox ventilation products enable a healthy indoor climate and are designed with today's needs in mind. Vallox products are known for their simple, elegant design, ease of use and silence. Vallox is the Home of Fresh air.

Organisation logo

Product information

Vallox 245 CFi RA12

Product nameVallox 245 CFi RA12
Product identificationAir handling units (AHU) as referred in standards NS-EN 1886, NS-EN 13053 and EN 13141-7. Vallox ventilation unit 245 CFi composing mainly of steel, aluminium, electronics and plastics. EPD follows additional requirements for construction products considered as Electronic or Electric Equipment (EEE).
Product descriptionVallox is a well-known company that has developed ventilation systems in Finland for 50 years. Vallox aims to develop ventilation systems that improve the quality of indoor air in homes and ultimately can promote good health. People spend up to 90% of their time indoors and breathe thousands of litres of air each day. Ventilation aims at creating healthy and cosy indoor air in the building. Healthy indoor air is crucial in terms of well-being, even though it is not as concrete as food, water or motion. It is important to pay attention to the exchange of air for the following reasons. 1. Cooking, dishwashing, washing, taking a sauna bath, washing clothes and breathing produce humidity, smokes and odours that are eliminated efficiently by ventilation. 2. Low oxygen content causes headaches and fatigue. Efficient ventilation keeps the carbon dioxide level sufficiently low and makes the residents feel better and more active. 3. Ventilation removes the emissions caused by construction and furnishing materials from indoor air. In the traditional way of building, indoor air quality was taken care of with the help of natural ventilation, based on pressure differences caused by the differences in height and temperature and by the wind. The pressure difference made stuffy air and humidity go out via the flues, whereas fresh replacement air came in as leaks through window chinks or openings built for replacement air. In homes built or renovated in the modern way to be tight, natural ventilation is no longer a sufficient way of guaranteeing good indoor air. Today's living habits lead to a high humidity load indoors as it is usual to take a shower several times a day and clothes are washed and dried indoors. As the vapour barrier and tight windows do not let fresh air in, humidity cannot escape. It is therefore necessary to deal with ventilation mechanically. Vallox ventilation units are reliable and energy efficient. They have been designed and manufactured in Finland. The selection includes suitable ventilation units for different uses, sizes and needs. Vallox ventilation units have an estimated average lifetime of 25 years. Vallox ventilation units can be configured to different market areas and client needs and thus the naming of the unit may differ. The configuration that represents environmental impacts in this LCA and the EPD is the one with the biggest impact as it has been configured with all possible additional accessories (MyVallox Touch Panel, and an aluminum Heat Recovery Cell (HRC). Other cell configuration is an enthalpy cell consisting of plastic and steel. The MyVallox 245 CFi RA12 is a ventilation unit that has been configured with all possible components. Outside the scope of this LCA are the optional sensors for the ventilation units as they are individual products.
Product information from external sourceshttps://www.vallox.com/tuote/myvallox-245-cfi/
Technical purpose of productThe technical purpose of the Vallox 245 CFi is to provide controlled, energy-efficient mechanical ventilation for homes and other buildings, ensuring healthy indoor air quality
Manufacturing or service provision descriptionProduction process of Vallox ventilation units include steel sheet supply, sheet cutting, sheet bending, painting, final assembly, final product testing, packaging and logistics.
Material propertiesMass per piece: 207.8 kg/piece
Mass per piece:
207.8 kg/piece
Manufacturing siteVallox Oy Loimaa Myllykyläntie 9-11 32200 Loimaa Finland
UN CPC code54632. Ventilation and air conditioning equipment installation services
Geographical scopeEurope, Finland
Geographical scope descriptionProduction facility for the ventilation unit is Loimaa, Finland. The intended market for the products are widely used in different parts of Europe.
Actual or technical lifespan25 year(s)

Product images

Vallox 245 CFi RA02

Product nameVallox 245 CFi RA02
Product identificationAir handling units (AHU) as referred in standards NS-EN 1886, NS-EN 13053 and EN 13141-7. Vallox ventilation unit 245 CFi composing mainly of steel, aluminium, electronics and plastics. EPD follows additional requirements for construction products considered as Electronic or Electric Equipment (EEE).
Product descriptionVallox is a well-known company that has developed ventilation systems in Finland for 50 years. Vallox aims to develop ventilation systems that improve the quality of indoor air in homes and ultimately can promote good health. People spend up to 90% of their time indoors and breathe thousands of litres of air each day. Ventilation aims at creating healthy and cosy indoor air in the building. Healthy indoor air is crucial in terms of well-being, even though it is not as concrete as food, water or motion. It is important to pay attention to the exchange of air for the following reasons. 1. Cooking, dishwashing, washing, taking a sauna bath, washing clothes and breathing produce humidity, smokes and odours that are eliminated efficiently by ventilation. 2. Low oxygen content causes headaches and fatigue. Efficient ventilation keeps the carbon dioxide level sufficiently low and makes the residents feel better and more active. 3. Ventilation removes the emissions caused by construction and furnishing materials from indoor air. In the traditional way of building, indoor air quality was taken care of with the help of natural ventilation, based on pressure differences caused by the differences in height and temperature and by the wind. The pressure difference made stuffy air and humidity go out via the flues, whereas fresh replacement air came in as leaks through window chinks or openings built for replacement air. In homes built or renovated in the modern way to be tight, natural ventilation is no longer a sufficient way of guaranteeing good indoor air. Today's living habits lead to a high humidity load indoors as it is usual to take a shower several times a day and clothes are washed and dried indoors. As the vapour barrier and tight windows do not let fresh air in, humidity cannot escape. It is therefore necessary to deal with ventilation mechanically. Vallox ventilation units are reliable and energy efficient. They have been designed and manufactured in Finland. The selection includes suitable ventilation units for different uses, sizes and needs. Vallox ventilation units have an estimated average lifetime of 25 years. Vallox ventilation units can be configured to different market areas and client needs and thus the naming of the unit may differ. The configuration that represents environmental impacts in this LCA and the EPD is the one with the biggest impact as it has been configured with all possible additional accessories (MyVallox Touch Panel, and an aluminum Heat Recovery Cell (HRC). Other cell configuration is an enthalpy cell consisting of plastic and steel. Outside the scope of this LCA are the optional sensors for the ventilation units as they are individual products.
Product information from external sourceshttps://www.vallox.com/tuote/myvallox-245-cfi/
Technical purpose of productThe technical purpose of the Vallox 245 CFi is to provide controlled, energy-efficient mechanical ventilation for homes and other buildings, ensuring healthy indoor air quality
Manufacturing or service provision descriptionProduction process of Vallox ventilation units include steel sheet supply, sheet cutting, sheet bending, painting, final assembly, final product testing, packaging and logistics.
Material propertiesMass per piece: 207.6 kg/piece
Mass per piece:
207.6 kg/piece
Manufacturing siteVallox Oy Loimaa Myllykyläntie 9-11 32200 Loimaa Finland
UN CPC code54632. Ventilation and air conditioning equipment installation services
Geographical scopeEurope, Finland
Geographical scope descriptionProduction facility for the ventilation unit is Loimaa, Finland. The intended market for the products are widely used in different parts of Europe.
Actual or technical lifespan25 year(s)

Product images

Vallox 245 CFi RE02

Product nameVallox 245 CFi RE02
Product identificationAir handling units (AHU) as referred in standards NS-EN 1886, NS-EN 13053 and EN 13141-7. Vallox ventilation unit 245 CFi composing mainly of steel, aluminium, electronics and plastics. EPD follows additional requirements for construction products considered as Electronic or Electric Equipment (EEE).
Product descriptionVallox is a well-known company that has developed ventilation systems in Finland for 50 years. Vallox aims to develop ventilation systems that improve the quality of indoor air in homes and ultimately can promote good health. People spend up to 90% of their time indoors and breathe thousands of litres of air each day. Ventilation aims at creating healthy and cosy indoor air in the building. Healthy indoor air is crucial in terms of well-being, even though it is not as concrete as food, water or motion. It is important to pay attention to the exchange of air for the following reasons. 1. Cooking, dishwashing, washing, taking a sauna bath, washing clothes and breathing produce humidity, smokes and odours that are eliminated efficiently by ventilation. 2. Low oxygen content causes headaches and fatigue. Efficient ventilation keeps the carbon dioxide level sufficiently low and makes the residents feel better and more active. 3. Ventilation removes the emissions caused by construction and furnishing materials from indoor air. In the traditional way of building, indoor air quality was taken care of with the help of natural ventilation, based on pressure differences caused by the differences in height and temperature and by the wind. The pressure difference made stuffy air and humidity go out via the flues, whereas fresh replacement air came in as leaks through window chinks or openings built for replacement air. In homes built or renovated in the modern way to be tight, natural ventilation is no longer a sufficient way of guaranteeing good indoor air. Today's living habits lead to a high humidity load indoors as it is usual to take a shower several times a day and clothes are washed and dried indoors. As the vapour barrier and tight windows do not let fresh air in, humidity cannot escape. It is therefore necessary to deal with ventilation mechanically. Vallox ventilation units are reliable and energy efficient. They have been designed and manufactured in Finland. The selection includes suitable ventilation units for different uses, sizes and needs. Vallox ventilation units have an estimated average lifetime of 25 years. Vallox ventilation units can be configured to different market areas and client needs and thus the naming of the unit may differ. The configuration that represents environmental impacts in this LCA and the EPD is the one with the biggest impact as it has been configured with all possible additional accessories (MyVallox Touch Panel, and an aluminum Heat Recovery Cell (HRC). Other cell configuration is an enthalpy cell consisting of plastic and steel. Outside the scope of this LCA are the optional sensors for the ventilation units as they are individual products.
Product information from external sourceshttps://www.vallox.com/tuote/myvallox-245-cfi/
Technical purpose of productThe technical purpose of the Vallox 245 CFi is to provide controlled, energy-efficient mechanical ventilation for homes and other buildings, ensuring healthy indoor air quality
Manufacturing or service provision descriptionProduction process of Vallox ventilation units include steel sheet supply, sheet cutting, sheet bending, painting, final assembly, final product testing, packaging and logistics.
Material propertiesMass per piece: 204.4 kg/piece
Mass per piece:
204.4 kg/piece
Manufacturing siteVallox Oy Loimaa Myllykyläntie 9-11 32200 Loimaa Finland
UN CPC code54632. Ventilation and air conditioning equipment installation services
Geographical scopeEurope, Finland
Geographical scope descriptionProduction facility for the ventilation unit is Loimaa, Finland. The intended market for the products are widely used in different parts of Europe.
Actual or technical lifespan25 year(s)

Product images

Vallox 245 CFi RA00

Product nameVallox 245 CFi RA00
Product identificationAir handling units (AHU) as referred in standards NS-EN 1886, NS-EN 13053 and EN 13141-7. Vallox ventilation unit 245 CFi composing mainly of steel, aluminium, electronics and plastics. EPD follows additional requirements for construction products considered as Electronic or Electric Equipment (EEE).
Product descriptionVallox is a well-known company that has developed ventilation systems in Finland for 50 years. Vallox aims to develop ventilation systems that improve the quality of indoor air in homes and ultimately can promote good health. People spend up to 90% of their time indoors and breathe thousands of litres of air each day. Ventilation aims at creating healthy and cosy indoor air in the building. Healthy indoor air is crucial in terms of well-being, even though it is not as concrete as food, water or motion. It is important to pay attention to the exchange of air for the following reasons. 1. Cooking, dishwashing, washing, taking a sauna bath, washing clothes and breathing produce humidity, smokes and odours that are eliminated efficiently by ventilation. 2. Low oxygen content causes headaches and fatigue. Efficient ventilation keeps the carbon dioxide level sufficiently low and makes the residents feel better and more active. 3. Ventilation removes the emissions caused by construction and furnishing materials from indoor air. In the traditional way of building, indoor air quality was taken care of with the help of natural ventilation, based on pressure differences caused by the differences in height and temperature and by the wind. The pressure difference made stuffy air and humidity go out via the flues, whereas fresh replacement air came in as leaks through window chinks or openings built for replacement air. In homes built or renovated in the modern way to be tight, natural ventilation is no longer a sufficient way of guaranteeing good indoor air. Today's living habits lead to a high humidity load indoors as it is usual to take a shower several times a day and clothes are washed and dried indoors. As the vapour barrier and tight windows do not let fresh air in, humidity cannot escape. It is therefore necessary to deal with ventilation mechanically. Vallox ventilation units are reliable and energy efficient. They have been designed and manufactured in Finland. The selection includes suitable ventilation units for different uses, sizes and needs. Vallox ventilation units have an estimated average lifetime of 25 years. Vallox ventilation units can be configured to different market areas and client needs and thus the naming of the unit may differ. The configuration that represents environmental impacts in this LCA and the EPD is the one with the biggest impact as it has been configured with all possible additional accessories (MyVallox Touch Panel, and an aluminum Heat Recovery Cell (HRC). Other cell configuration is an enthalpy cell consisting of plastic and steel. Outside the scope of this LCA are the optional sensors for the ventilation units as they are individual products.
Product information from external sourceshttps://www.vallox.com/tuote/myvallox-245-cfi/
Technical purpose of productThe technical purpose of the Vallox 245 CFi is to provide controlled, energy-efficient mechanical ventilation for homes and other buildings, ensuring healthy indoor air quality
Manufacturing or service provision descriptionProduction process of Vallox ventilation units include steel sheet supply, sheet cutting, sheet bending, painting, final assembly, final product testing, packaging and logistics.
Material propertiesMass per piece: 205.9 kg/piece
Mass per piece:
205.9 kg/piece
Manufacturing siteVallox Oy Loimaa Myllykyläntie 9-11 32200 Loimaa Finland
UN CPC code54632. Ventilation and air conditioning equipment installation services
Geographical scopeEurope, Finland
Geographical scope descriptionProduction facility for the ventilation unit is Loimaa, Finland. The intended market for the products are widely used in different parts of Europe.
Actual or technical lifespan25 year(s)

Product images

Vallox 245 CFi RE00

Product nameVallox 245 CFi RE00
Product identificationAir handling units (AHU) as referred in standards NS-EN 1886, NS-EN 13053 and EN 13141-7. Vallox ventilation unit 245 CFi composing mainly of steel, aluminium, electronics and plastics. EPD follows additional requirements for construction products considered as Electronic or Electric Equipment (EEE).
Product descriptionVallox is a well-known company that has developed ventilation systems in Finland for 50 years. Vallox aims to develop ventilation systems that improve the quality of indoor air in homes and ultimately can promote good health. People spend up to 90% of their time indoors and breathe thousands of litres of air each day. Ventilation aims at creating healthy and cosy indoor air in the building. Healthy indoor air is crucial in terms of well-being, even though it is not as concrete as food, water or motion. It is important to pay attention to the exchange of air for the following reasons. 1. Cooking, dishwashing, washing, taking a sauna bath, washing clothes and breathing produce humidity, smokes and odours that are eliminated efficiently by ventilation. 2. Low oxygen content causes headaches and fatigue. Efficient ventilation keeps the carbon dioxide level sufficiently low and makes the residents feel better and more active. 3. Ventilation removes the emissions caused by construction and furnishing materials from indoor air. In the traditional way of building, indoor air quality was taken care of with the help of natural ventilation, based on pressure differences caused by the differences in height and temperature and by the wind. The pressure difference made stuffy air and humidity go out via the flues, whereas fresh replacement air came in as leaks through window chinks or openings built for replacement air. In homes built or renovated in the modern way to be tight, natural ventilation is no longer a sufficient way of guaranteeing good indoor air. Today's living habits lead to a high humidity load indoors as it is usual to take a shower several times a day and clothes are washed and dried indoors. As the vapour barrier and tight windows do not let fresh air in, humidity cannot escape. It is therefore necessary to deal with ventilation mechanically. Vallox ventilation units are reliable and energy efficient. They have been designed and manufactured in Finland. The selection includes suitable ventilation units for different uses, sizes and needs. Vallox ventilation units have an estimated average lifetime of 25 years. Vallox ventilation units can be configured to different market areas and client needs and thus the naming of the unit may differ. The configuration that represents environmental impacts in this LCA and the EPD is the one with the biggest impact as it has been configured with all possible additional accessories (MyVallox Touch Panel, and an aluminum Heat Recovery Cell (HRC). Other cell configuration is an enthalpy cell consisting of plastic and steel. Outside the scope of this LCA are the optional sensors for the ventilation units as they are individual products.
Product information from external sourceshttps://www.vallox.com/tuote/myvallox-245-cfi/
Technical purpose of productThe technical purpose of the Vallox 245 CFi is to provide controlled, energy-efficient mechanical ventilation for homes and other buildings, ensuring healthy indoor air quality
Manufacturing or service provision descriptionProduction process of Vallox ventilation units include steel sheet supply, sheet cutting, sheet bending, painting, final assembly, final product testing, packaging and logistics.
Material propertiesMass per piece: 202.8 kg/piece
Mass per piece:
202.8 kg/piece
Manufacturing siteVallox Oy Loimaa Myllykyläntie 9-11 32200 Loimaa Finland
UN CPC code54632. Ventilation and air conditioning equipment installation services
Geographical scopeEurope, Finland
Geographical scope descriptionProduction facility for the ventilation unit is Loimaa, Finland. The intended market for the products are widely used in different parts of Europe.
Actual or technical lifespan25 year(s)

Product images

Technical characteristics and performance

c-PCR-018: Air handling units (AHU) and fans

Product nameElement descriptionWeight (kg)Airflow (m3/hr)Annual energy consumption (kWh)Annual Use HoursClimate Zone used for Energy CalculationPressure drop (Pa)SFP
Vallox 245 CFi RA12Ventilation unit with Controller and Aluminium Heat Recovery Cell207.881312868760 Southern Finland Helsinki-Vantaa (TRY 2020)
Vallox 245 CFi RA02Ventilation unit without controller and aluminium heat recovery cell207.681312868760 Southern Finland Helsinki-Vantaa (TRY 2020)
Vallox 245 CFi RE02Ventilation unit without controller and enthalpy heat recovery cell204.481312868760 Southern Finland Helsinki-Vantaa (TRY 2020)
Vallox 245 CFi RA00Ventilation unit without controller and aluminium heat recovery cell, no heating resistor205.981312868760 Southern Finland Helsinki-Vantaa (TRY 2020)
Vallox 245 CFi RE00Ventilation unit without controller and enthalpy heat recovery cell, no heating resistor202.881312868760 Southern Finland Helsinki-Vantaa (TRY 2020)

Content declaration

Content declaration of multiple productsContent declaration is representative for 245 CFi RA12. Difference in contents when compared to RA12: RA02: 0.2 kg less electronics RE02: 3.78 kg less aluminium, 0.2 kg less electronics, 0.6 kg more plastics RA00: 1.57 kg less electronics, 0.12 kg less plastics, 0.16 kg less steel RE00: 3.78 kg less aluminium, 1.57 kg less electronics, 0.16 kg less steel, 0.48 kg more plastics
Hazardous and toxic substancesThe product does not contain any substances from the SVHC candidate list in concentrations exceeding 0.1% of its weight.
Product content
Content nameMass, kgPost-consumer recycled material, mass-% of productBiogenic material, mass-% of productBiogenic material1, kg C/declared unit
Steel139.45000
Aluminium27.8000
Electronics9.63000
Plastics22.0700
Other3.91000
Total202.86000
Note 11 kg biogenic carbon is equivalent to 44/12 kg of CO2
Packaging materials
Material nameMass, kgMass-% (versus the product)Biogenic material1, kg C/declared unit
Cardboard4.852.390.0098
Paper (manuals etc.)0.0880.040.00018
Wooden pallet1.20.590.0027
Total6.1383.020.01268
Note 11 kg biogenic carbon is equivalent to 44/12 kg of CO2

LCA information

EPD based on declared or functional unitDeclared unit
Declared unit and reference flow1 ventilation unit maintained for 25 years Number of pieces: 1 piece(s)
Conversion factor to mass0.00481
Are infrastructure or capital goods included in any upstream, core or downstream processes?
Do infrastructure and capital goods contribute more than 10% to the A1-A3 (A1-A5 for services) results of any environmental impact indicator declared in the EPD?
Datasources used for this EPDecoinvent database (general) ecoinvent 3.11 database Other database Industry data 2.0
LCA SoftwareSimaPro 10.2
Version of the EN 15804 reference packageEF Reference Package 3.1
Characterisation methodsLCA follows the JRC characterization factors (E.F) version 3.1.
Technology description including background systemMain materials/components used for Vallox ventilation units are steel, aluminum, plastics and electronics. The main frame and doors are made from steel plates that are cut, bent etc. in Loimaa factory, other components are sub-assembled before transport to the factory. The ready product is transported to various locations across Europe. During the use of the product (Reference Service Life: 25 years) electricity is consumed and filters (2 different types) are replaced annually. After the 25 years, the unit is disposed as indicated in the EPD.
Scrap (recycled material) inputs contribution levelLess than 10% of the GWP-GHG results in modules A1-A3 come from scrap inputs

Data quality assessment

Description of data quality assessment and reference yearsThe overall data used for the LCA is fair/good. The reference year for collected data is 2025. Most of the inventory data came from Vallox internal systems and calculations. Largest share of A1-A3 impact originates from supplier EPD data. Use phase and End-of-Life data is overall average and based on generic datasets that however represent the system on a good level. Data quality was assessed as per data quality level and criteria of the UN Environment Global Guidance on LCA database development, Product Environmental Footprint criteria and reflected upon EN 15941.
Data quality assessment
Process nameSource typeSourceReference yearData categoryShare of primary data, of GWP-GHG results for A1-A3
Raw material extractionPDM, ERP and external databaseEcoinvent 3.11, Industry data 2.02025Primary and secondary data0%
Raw material extractionEPDSupplier EPD's2023Primary and secondary data24.6%
Transportation of raw materialsERP and external databaseEcoinvent 3.112025Primary and secondary data0.02%
Manufacturing of productERP, environmental report and external databaseEcoinvent 3.112025Primary and secondary data4.55%
Total share of primary data, of GWP-GHG results for A1-A329.17%
The share of primary data is calculated based on GWP-GHG results. It is a simplified indicator for data quality that supports the use of more primary data to increase the representativeness of and comparability between EPDs. Note that the indicator does not capture all relevant aspects of data quality and is not comparable across product categories.
Comment on the data sources and other information in the tableHeat recovery cell supplier EPD's could not be fully confirmed to align with EN 15804. The results in the EPD have been checked and they represent the heat recovery cell better than a possible generic dataset combination. Due to non-confirmed EN 15804 compliance the specific data share for these EPD's are '0'.
Electricity data
Electricity used in the manufacturing process in A3 (A5 for services)
Type of electricity mixSpecific electricity mix as generated, or purchased from an electricity supplier, demonstrated by a contractual instrument
Energy sourcesHydro0%
Wind100%
Solar0%
Biomass0%
Geothermal0%
Waste0%
Nuclear0%
Natural gas0%
Coal0%
Oil0%
Peat0%
Other0%
GWP-GHG intensity (kg CO2 eq./kWh)0.03 kg CO2 eq./kWh

System boundary

Description of the system boundaryc) Cradle to grave and module D (A + B + C + D).
Excluded modulesNo, there is no excluded module, or there are no excluded modules

Declared modules

Product stageConstruction process stageUse stageEnd of life stageBeyond product life cycle
Raw material supplyTransportManufacturingTransport to siteConstruction installationUseMaintenanceRepairReplacementRefurbishmentOperational energy useOperational water useDe-construction demolitionTransportWaste processingDisposalReuse-Recovery-Recycling-potential
ModuleA1A2A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
Modules declaredXXXXXXXXXXXXXXXXX
GeographyEuropeEuropeFinlandEuropeEuropeEuropeEuropeEuropeEuropeEuropeEuropeEuropeEuropeEuropeEuropeEuropeEurope
Share of specific data29.17%--------------
Variation - products6.7%--------------
Variation - sites0%--------------
DisclaimerThe share of specific/primary data and both variations (products and sites) refer to GWP-GHG results only.

Description of the process flow diagram(s)

System cut-off description: In C3, for resource use indicators the paper used as energy production material was not considered due to minimal effect. Cardboard used for packaging could be also recycled to module D but in this LCA the conservative approach was to include the full impacts in module A5. In addition, the cardboard in module A5 was mostly already produced with recycled inputs, no benefits should be accounted for. In module D, steel fastener recycled inputs have not been considered due to very minimal mass

Process flow diagram(s) related images

Default scenario

Name of the default scenarioVentilation unit life cycle
Description of the default scenarioLife cycle inventory was collected for 245 CFi RA12, 245 CFi RA02, 245 CFi RA00 and 245CFi RE00. The product stage (A1-A3) considers the manufacturing of raw materials, their transportation to the production facility and the stages of the product manufacturing process. The scenarios included for A4-D are currently in use and are representative for one of the most probable alternatives.

Module A4: Transport to the building site

Explanatory name of the default scenario in module A4Transport to customer
Brief description of the default scenario in module A4As indicated in c-PCR-018 Ventilation components.
Description of the default scenario in module A4Transportation to use was calculated as a conservative scenario as indicated in c-PCR-018 Ventilation components. Transport distance used was 154 km from Loimaa factory to capital of Finland, Helsinki and 300 km as the distance to a distributor.
Module A4 informationValueUnit
Distance
454
km
Transported mass207.8
kg

Module A5: Installation in the building

Explanatory name of the default scenario in module A5Installation
Brief description of the default scenario in module A5Installation process consists of processing and disposal of packaging materials.
Description of the default scenario in module A5During the installation process, the packaging is disposed of. The scenario includes the transportation of the packaging to waste treatment. Biogenic carbon leaves the product system with the cardboard packaging. The biogenic carbon amount is declared in the content declaration.
Module A5 informationValueUnit
Transport to waste treatment100
km
Packaging waste4.85
kg

Module B1: Use

Explanatory name of the default scenario in module B1Use
Brief description of the default scenario in module B1No use emissions were considered to occur.
Description of the default scenario in module B1As no use emissions were considered to occur, B1 module has no inputs or outputs.

Module B2: Maintenance

Explanatory name of the default scenario in module B2Filter maintenance
Brief description of the default scenario in module B2Filter replacement twice per year during the life cycle of the ventilation unit.
Description of the default scenario in module B2Filters are replaced by assumption twice per year during the life cycle of the ventilation unit. Filters are manufactured for use in Europe and Finland, used and disposed as municipal solid waste after use in Europe. Transports of the filters were also included and the transport scenario was similar to A4.
Module B2 informationValueUnit
Maintenance process
Filter replacement
Maintenance cycle
2
per year

Module B3: Repair

Explanatory name of the default scenario in module B3Repair
Brief description of the default scenario in module B3No use emissions were considered to occur.
Description of the default scenario in module B3As no use emissions were considered to occur, B3 module has no input or outputs.

Module B4: Replacement

Explanatory name of the default scenario in module B4Blower replacement
Brief description of the default scenario in module B4Blower replacement once during the life cycle of the ventilation unit.
Description of the default scenario in module B4Blower is replaced once during the life cycle of the ventilation unit. Blowers are manufactured for use in Europe and Finland, used, transported for waste processing (100 km) and disposed as municipal solid waste after use in Europe. Transports of the fan units were also included, and the transport scenario was similar to A4.
Module B4 informationValueUnit
Replacement process
Blower fan replacement
Replacement cycle
1

Module B5: Refurbishment

Explanatory name of the default scenario in module B5Refurbishment
Brief description of the default scenario in module B5There are no regular refurbishment processes.
Description of the default scenario in module B5As there are no regular refurbishment processes, B5 has no inputs or outputs.

Module B6: Operational energy use

Explanatory name of the default scenario in module B6Operational energy use
Brief description of the default scenario in module B6Operational energy use of the ventilation unit during the life cycle.
Description of the default scenario in module B6Vallox ventilation units are connected to a 230 V / 50 Hz electrical outlet. Electric current is mostly used to control the blower fan(s) and airflow. The energy consumption thus in module B6 comes from the usage of the ventilation unit. Technical information of the product can be found from Vallox’s website. Annual electricity consumption is based on calculations complying with Commission Delegated Regulation (EU) No 1254/2014 of 11 July 2014. Working point defined in the Ecodesign Directive (2009/125/EC), Southern Finland, Helsinki-Vantaa TRY year 2020. EN 13141-7 is applied for the calculations and Vallox MySelecta software has been used to run the calculation. Further technical specifications regarding electricity consumption can be found from Vallox website. The annual use hours are 8760h (24h/d for 365 days). As the Vallox ventilation units are used all over Europe, an average market dataset for European low voltage electricity was used (Electricity, low voltage {Europe without Switzerland} | market group for electricity, low voltage | Cut-off, S). The IPCC 2021 GWP100 factor for the used dataset was 0,336 kg CO2 eq. / kWh. For use phase electricity usage, the annual electricity consumption of the 245 CFi was multiplied by the 25 years it is in use in average: 1 286 kWh⁄a*25 a= 32 150 kWh
Module B6 informationValueUnit
Electricity consumption during RSL32 150
kWh/RSL

Module B7: Operational water use

Explanatory name of the default scenario in module B7Operational water use
Brief description of the default scenario in module B7There is no operational water use.
Description of the default scenario in module B7As there is no operational water use, B7 has no inputs or outputs.

Module C: End-of-life

Explanatory name of the default scenario in module CEnd-of-life
Brief description of the default scenario in module CDeconstruction, transport to waste processing and waste processing.
Description of the default scenario in module CEnd-of-Life scenario in this EPD represents a 100% recycling scenario. Waste processing and disposal was modeled as a conservative scenario as indicated in c-PCR-018 and the share of materials entering different waste treatment processes during the recycling scenario was retrieved from Eurostat waste databases. An average of 27 EU countries was used. After Module C4, materials are assumed to have reached end‑of‑waste status within the system boundary. Recycled steel and aluminium are assumed to substitute primary materials, with resulting benefits reported in Module D.
Module C informationValueUnit
C2: Distance to waste treatment (lorry)100
km
C3: Material to recycling/incineration with energy recovery198.03
kg
C4: Material to final disposal1.97
kg

Reference service life

Description of the default scenario in reference service lifeRSL is defined by Vallox as 25 years. The statement is made by Vallox’s Quality and Development Manager Sari Ponkala. This guarantee fulfils the requirement set in the c-PCR-018 for ventilation component.
Reference service life informationValueUnit
Reference service life
25
year(s)

Module D: Beyond product life cycle

Explanatory name of the default scenario in module DResource recovery stage
Brief description of the default scenario in module DThe benefits of recyclable materials.
Description of the default scenario in module DThe benefits of recycled metals in module C3 were considered to have a possible environmental benefit as subsituted material. Packaging cardboard leaving module A5 could be seen to have potential if it would be recycled or incinerated for energy.
Module D informationValueUnit
Aluminium recovered in Module D99.6
%
Steel recovered in Module D99.7
%

Environmental performance

The estimated impact results are only relative statements, which do not indicate the endpoints of the impact categories, exceeding threshold values, safety margins and/or risks.

Mandatory environmental performance indicators according to EN 15804

Impact categoryIndicatorUnitA1-A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
Climate change - totalGWP-totalkg CO2 eq.1.32E+31.76E+12.22E+00.00E+02.46E+20.00E+04.95E+10.00E+01.08E+40.00E+00.00E+03.91E+04.94E+11.79E+0-2.80E+2
Climate change - fossilGWP-fossilkg CO2 eq.1.30E+31.76E+18.75E-10.00E+02.46E+20.00E+04.94E+10.00E+01.07E+40.00E+00.00E+03.88E+04.93E+16.99E-1-2.80E+2
Climate change - biogenicGWP-biogenickg CO2 eq.2.09E+11.18E-21.35E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+02.75E-21.33E-11.09E+02.59E+0
Climate change - land use and land-use changeGWP-luluckg CO2 eq.2.74E+05.94E-39.44E-50.00E+01.26E-10.00E+01.46E-10.00E+03.17E+10.00E+00.00E+01.32E-35.60E-32.96E-5-2.14E+0
Ozone depletionODPkg CFC-11 eq.4.23E-53.84E-71.27E-80.00E+05.12E-50.00E+07.08E-70.00E+01.99E-40.00E+00.00E+08.46E-88.06E-81.72E-9-1.53E-6
AcidificationAPmol H+ eq.6.23E+03.78E-24.45E-30.00E+07.58E-10.00E+04.31E-10.00E+06.17E+10.00E+00.00E+08.33E-32.60E-28.53E-4-9.97E-1
Eutrophication aquatic freshwaterEP-freshwaterkg P eq.4.17E-21.31E-42.22E-60.00E+05.05E-30.00E+03.44E-30.00E+01.07E+00.00E+00.00E+02.89E-51.45E-49.54E-6-5.02E-3
Eutrophication aquatic marineEP-marinekg N eq.1.19E+08.88E-32.00E-30.00E+02.20E-10.00E+03.52E-10.00E+07.60E+00.00E+00.00E+01.96E-37.26E-31.85E-3-1.39E-1
Eutrophication terrestrialEP-terrestrialmol N eq.1.13E+19.83E-22.13E-20.00E+01.84E+00.00E+05.92E-10.00E+08.72E+10.00E+00.00E+02.17E-27.96E-23.73E-3-1.37E+0
Photochemical ozone formationPOCPkg NMVOC eq.3.57E+06.00E-28.50E-30.00E+01.14E+00.00E+01.96E-10.00E+02.79E+10.00E+00.00E+01.32E-22.57E-21.22E-3-6.16E-1
Depletion of abiotic resources - minerals and metalsADP-minerals&metals1, 2kg Sb eq.2.86E-26.04E-55.72E-70.00E+01.51E-30.00E+03.96E-30.00E+01.43E-10.00E+00.00E+01.33E-53.14E-51.72E-7-6.46E-4
Depletion of abiotic resources - fossil fuelsADP-fossil1MJ, net calorific value1.28E+42.50E+21.10E+10.00E+05.83E+30.00E+06.73E+20.00E+02.46E+50.00E+00.00E+00.00E+07.14E+11.04E+0-3.22E+3
Water useWDP1m3 world eq. deprived7.01E+21.28E+02.39E-20.00E+06.27E+10.00E+02.49E+10.00E+05.88E+30.00E+00.00E+05.67E-22.07E+09.91E-4-4.95E+2
AcronymsGWP-fossil = Global Warming Potential fossil fuels; GWP-biogenic = Global Warming Potential biogenic; GWP-luluc = Global Warming Potential land use and land use change; ODP = Depletion potential of the stratospheric ozone layer; AP = Acidification potential, Accumulated Exceedance; EP-freshwater = Eutrophication potential, fraction of nutrients reaching freshwater end compartment; EP-marine = Eutrophication potential, fraction of nutrients reaching marine end compartment; EP-terrestrial = Eutrophication potential, Accumulated Exceedance; POCP = Formation potential of tropospheric ozone; ADP-minerals&metals = Abiotic depletion potential for non-fossil resources; ADP-fossil = Abiotic depletion for fossil resources potential; WDP = Water (user) deprivation potential, deprivation-weighted water consumption
General disclaimerThe results of the end-of-life stage (modules C1-C4) should be considered when using the results of the product stage (modules A1-A3/A1-A5 for services).
Disclaimer 1The results of this environmental impact indicator shall be used with care as the uncertainties of these results are high or as there is limited experience with the indicator
Disclaimer 2The results of the impact categories abiotic depletion of minerals and metals may be highly uncertain in LCAs that include capital goods/infrastructure in generic datasets, in case infrastructure/capital goods contribute greatly to the total results. This is because the LCI data of infrastructure/capital goods used to quantify these indicators in currently available generic datasets sometimes lack temporal, technological and geographical representativeness. Caution should be exercised when using the results of these indicators for decision-making purposes.

Additional mandatory environmental performance indicators

Impact categoryIndicatorUnitA1-A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
Climate change - GWP-GHGGWP-GHG1kg CO2 eq.1.31E+31.76E+18.93E-10.00E+02.61E+20.00E+04.96E+10.00E+01.08E+40.00E+00.00E+03.88E+04.93E+11.13E+0-2.82E+2
AcronymsGWP-GHG = Global warming potential greenhouse gas.
General disclaimerThe results of the end-of-life stage (modules C1-C4) should be considered when using the results of the product stage (modules A1-A3/A1-A5 for services).
Disclaimer 1The GWP-GHG indicator is termed GWP-IOBC/GHG in the ILCD+EPD+ data format. The indicator accounts for all greenhouse gases except biogenic carbon dioxide uptake and emissions and biogenic carbon stored in the product. As such, the indicator is identical to GWP-total except that the CF for biogenic CO2 is set to zero.

Additional voluntary environmental performance indicators according to EN 15804

Impact categoryIndicatorUnitA1-A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
Particulate matter emissionsPMDisease incidence6.43E-51.31E-61.10E-70.00E+08.08E-60.00E+05.33E-60.00E+01.89E-40.00E+00.00E+02.30E-73.41E-71.53E-8-1.27E-5
Ionizing radiation - human healthIRP1kBq U235 eq.3.68E+31.09E-11.34E-30.00E+05.13E+00.00E+07.29E+00.00E+02.14E+30.00E+00.00E+02.41E-21.29E-18.66E-44.49E+3
Eco-toxicity - freshwaterETP-fw2, 3CTUe1.78E+43.36E+19.09E-10.00E+01.22E+30.00E+02.02E+30.00E+03.52E+40.00E+00.00E+07.40E+06.66E+18.56E+0-2.70E+2
Human toxicity - cancer effectsHTP-c2, 3CTUh1.22E-62.96E-97.79E-110.00E+05.66E-80.00E+01.40E-70.00E+03.18E-60.00E+00.00E+06.48E-103.94E-94.68E-10-2.50E-7
Human toxicity - non-cancer effectsHTP-nc2, 3CTUh2.73E-51.58E-72.10E-90.00E+01.90E-60.00E+02.44E-60.00E+01.73E-40.00E+00.00E+03.46E-81.96E-79.57E-9-8.44E-7
Land-use related impacts/soil qualitySQP2, 3Dimensionless4.80E+31.50E+21.25E+00.00E+06.59E+20.00E+04.96E+20.00E+04.79E+40.00E+00.00E+03.31E+13.22E+11.02E+0-2.63E+1
AcronymsPM = Potential incidence of disease due to particulate matter emissions; IRP = Potential human exposure efficiency relative to U235; ETP-fw = Potential comparative toxic unit for ecosystems; HTP-c = Potential comparative toxic unit for humans; HTP-nc = Potential comparative toxic unit for humans; SQP = Potential soil quality index.
General disclaimerThe results of the end-of-life stage (modules C1-C4) should be considered when using the results of the product stage (modules A1-A3/A1-A5 for services).
Disclaimer 1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
Disclaimer 2The results of this environmental impact indicator shall be used with care as the uncertainties of these results are high or as there is limited experience with the indicator.
Disclaimer 3The results of the impact categories land use, human toxicity (cancer), human toxicity, noncancer and ecotoxicity (freshwater) may be highly uncertain in LCAs that include capital goods/infrastructure in generic datasets, in case infrastructure/capital goods contribute greatly to the total results. This is because the LCI data of infrastructure/capital goods used to quantify these indicators in currently available generic datasets sometimes lack temporal, technological and geographical representativeness. Caution should be exercised when using the results of these indicators for decision-making purposes.

Resource use indicators according to EN 15804

IndicatorUnitA1-A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
PEREMJ, net calorific value2.55E+34.13E+04.87E-20.00E+01.72E+20.00E+08.13E+10.00E+06.52E+40.00E+00.00E+09.09E-14.98E+03.12E-2-4.43E+2
PERMMJ, net calorific value1.81E+00.00E+0-1.81E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+0
PERTMJ, net calorific value2.55E+34.13E+0-1.76E+00.00E+01.72E+20.00E+08.13E+10.00E+06.52E+40.00E+00.00E+09.09E-14.98E+03.12E-2-4.43E+2
PENREMJ, net calorific value1.17E+42.50E+21.10E+10.00E+05.83E+30.00E+06.74E+20.00E+02.46E+50.00E+00.00E+03.88E-37.14E+11.04E+0-3.22E+3
PENRMMJ, net calorific value8.15E+20.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+0-5.69E+2-2.46E+20.00E+0
PENRTMJ, net calorific value1.26E+42.50E+21.10E+10.00E+05.83E+30.00E+06.74E+20.00E+02.46E+50.00E+00.00E+03.88E-3-4.98E+2-2.45E+2-3.22E+3
SMkg3.91E+10.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+0
RSFMJ, net calorific value9.39E+01.49E-31.52E-50.00E+06.62E-20.00E+05.63E-20.00E+03.41E-10.00E+00.00E+00.00E+01.67E-39.53E-6-1.44E-3
NRSFMJ, net calorific value4.08E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+0
FWm31.30E+13.17E-25.77E-40.00E+01.52E+00.00E+06.07E-10.00E+01.58E+20.00E+00.00E+02.86E-35.05E-23.59E-54.34E+1
AcronymsPERE = Use of renewable primary energy excluding renewable primary energy resources used as raw materials; PERM = Use of renewable primary energy resources used as raw materials; PERT = Total use of renewable primary energy resources; PENRE = Use of non-renewable primary energy excluding non-renewable primary energy resources used as raw materials; PENRM = Use of non-renewable primary energy resources used as raw materials; PENRT = Total use of non-renewable primary energy re-sources; SM = Use of secondary material; RSF = Use of renewable secondary fuels; NRSF = Use of non-renewable secondary fuels; FW = Use of net fresh water.
General disclaimerThe results of the end-of-life stage (modules C1-C4) should be considered when using the results of the product stage (modules A1-A3/A1-A5 for services).

Waste indicators according to EN 15804

IndicatorUnitA1-A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
HWDkg2.44E+13.63E-18.64E-30.00E+09.97E+00.00E+06.78E+00.00E+05.99E+20.00E+00.00E+05.64E-28.23E-10.00E+0-2.33E+1
NHWDkg9.49E+27.79E+02.58E-10.00E+04.35E+20.00E+02.64E+20.00E+05.06E+40.00E+00.00E+06.07E-12.50E+13.36E+0-2.37E+2
RWDkg7.86E-27.46E-57.93E-70.00E+03.93E-30.00E+01.07E-20.00E+01.76E+00.00E+00.00E+00.00E+08.36E-50.00E+0-6.44E-3
AcronymsHWD = Hazardous waste disposed; NHWD = Non-hazardous waste disposed; RWD = Radioactive waste disposed.
General disclaimerThe results of the end-of-life stage (modules C1-C4) should be considered when using the results of the product stage (modules A1-A3/A1-A5 for services).

Output flow indicators according to EN 15804

IndicatorUnitA1-A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
CRUkg0.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+0
MFRkg6.31E+10.00E+04.85E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+01.55E+20.00E+00.00E+0
MERkg0.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+0
EEEMJ, net calorific value0.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+02.67E+20.00E+00.00E+0
EETMJ, net calorific value0.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+00.00E+0
AcronymsCRU = Components for re-use; MFR = Materials for recycling; MER = Materials for energy recovery; EEE = Exported electrical energy; EET = Exported thermal energy.
General disclaimerThe results of the end-of-life stage (modules C1-C4) should be considered when using the results of the product stage (modules A1-A3/A1-A5 for services).

Additional environmental information

To make a comparison of the effects of different energy production methods, a comparison was made. The comparison was made for European, Finnish and renewable low voltage electricity production. The assessment was made for 1 kWh and can be applied as a guideline. Only GWP100 results are included in this LCA to show the effect of energy source on environmental impacts.

The difference is substantial between electricity production methods: for EU average 0,34 kg CO2 eq. / kWH, for Finnish average 0,21 kg CO2 eq. / kWh and for renewable 0,02 kg CO2 eq. / kWh. The difference between renewable energy and EU average electricity is ~94 %.

Abbreviations

LCA = Life Cycle Assessment

EPD = Environmental Product Declaration

RSL = Reference Service Life

AHU = Air Handling Unit

EEE = Electrical and electronic equipment

SFP = Specific Fan Power

ISO = International Standardization Organization

PCR = Product Category Rule

NS-EN = Norsk Standard - European Standard (Harmonised)

kWh = kilowatt-hour

GWP = Global Warming Potential

REACH = Registration, Evaluation, Authorization and restriction of Chemicals

SVHC = Substance of very high concern

References

EcoInvent database version 3.11

EN15804-A2:2019. Sustainability of construction works - Environmental Product Declarations — Core rules for the product category of construction products

EPD International (2022): Product Category Rules (PCR) Construction products 2019:14, version 2.0

Eurostat. (n.d.). Waste Database. Retrieved February 20, 2025, from European Commission website: https://doi.org/10.2908/ENV_WASTRT

General Programme Instructions of the International EPD® System. Version 5.0

ISO 14025:2010 Environmental labels and declarations – Type III environmental declarations Principles and procedures.

ISO 14040:2006 Environmental management. Life cycle assessment. Principles and frameworks.

ISO 14044:2006 Environmental management. Life cycle assessment. Requirements and guidelines.

PCR 2019:14 Construction Products

PCR 2019:14-c-PCR-018 Ventilation components (c-PCR under PCR 2019:14) (Adopted from EPD Norway)

SimaPro 10.3

Worldsteel. Life cycle inventory (LCI) study 2020 data release. Available: https://worldsteel.org/wpcontent/uploads/Life-cycle-inventory-LCI-study-2020-data-release.pdf

Version history

Version 001, 2026-05-18

  • Original version of the EPD