EPD-IES-0022646:003

LB35 Door profile system (100NA, 101NA, 200NA, 202NA, 111NA, 212NA)

Used in all solutions with external sliding doors and insulating glass. Ideal for internal applications, like office partition walls, malls and airport separation areas. It perfectly suits the best architectural and design solutions. Single or double leaf sliding doors, with optional fixed side leaves. It can be installed on a transom or on a built-in self-supporting transom.

General information

EPD OwnerLabel s.p.a
Registration numberEPD-IES-0022646:003
PCR2019:14 Construction products (EN 15804+A2) 1.3.4
c-PCR2019:14-c-PCR-007 Being updated - Windows and doors (EN 17213) (c-PCR to PCR 2019:14) 1.0.0
StatusValid
Publication date2025-06-12
Valid until2030-06-12
EN 15804 compliantYes
Geographical scopeGlobal

Product images

Programme information

ProgrammeInternational EPD System
AddressEPD International AB Box 210 60 SE-100 31 Stockholm Sweden
Websitewww.environdec.com
E-mailsupport@environdec.com

Product category rules

CEN standard EN 15804 serves as the Core Product Category Rules (PCR)
Product Category Rules (PCR)2019:14 Construction products (EN 15804+A2) 1.3.4
PCR review was conducted byThe Technical Committee of the International EPD System. See www.environdec.com for a list of members. Review chair: Claudia A. Peña, University of Concepción, Chile. The review panel may be contacted via the Secretariat www.environdec.com/support.
Complementary Product Category Rules (c-PCR)2019:14-c-PCR-007 Being updated - Windows and doors (EN 17213) (c-PCR to PCR 2019:14) 1.0.0 Version: 1.0.0
c-PCR review was conducted byThe Technical Committee of the International EPD System

Verification

LCA accountabilityjtrabucco@staff.ambientesc.it, jtrabucco@staff.ambientesc.it, Label s.p.a
Independent third-party verification of the declaration and data, according to ISO 14025:2006, via
Third-party verifierGuido Croce (Unspecified company)
Approved byInternational EPD System
Procedure for follow-up of data during EPD validity involves third party verifier
*EPD Process Certification involves an accredited certification body certifying and periodically auditing the EPD process and conducting external and independent verification of EPDs that are regularly published. More information can be found in the General Programme Instructions on www.envrondec.com.

Ownership and limitation on use of EPD

Limitations

EPDs within the same product category but registered in different EPD programmes may not be comparable. For two EPDs to be comparable, they shall be based on the same PCR (including the same version number up to the first two digits) or be based on fully-aligned PCRs or versions of PCRs; cover products with identical functions, technical performances and use (e.g. identical declared/functional units); have equivalent system boundaries and descriptions of data; apply equivalent data quality requirements, methods of data collection, and allocation methods; apply identical cut-off rules and impact assessment methods (including the same version of characterisation factors); have equivalent content declarations; and be valid at the time of comparison.

Ownership

The EPD Owner has the sole ownership, liability, and responsibility for the EPD.

Information about EPD Owner

EPD OwnerLabel s.p.a
Contact person nameMarco Melis
Contact person e-mailm.melis@labelspa.it
Organisation addressItaly Parma 43126 Via U. Ilariuzzi 17/A

Description of the organisation of the EPD Owner

LABEL S.p.A. is a 100% Italian company with over 40 years of experience in the automatic door systems sector. LABEL S.p.A. designs and manufactures complete automatic entrance solutions, offering a wide range of high-performance frames and hospital panels. We are active in the healthcare and public sectors, where safety, hygiene, quality, and durability are essential requirements.

Organisation images

Organisation logo

Product information

Product nameLB35 Door profile system
Product identificationDoor profile system. The system meets the safety requirements provided for by Standard EN 16005. LB35 DOORS CODE INCLUDED: LB35 100NA - LB35 Door Single Slide Opening LB35 101NA - LB35 Door Single Slide Opening with Side Screen LB35 200NA - LB35 Door Bi-Part Opening LB35 202NA - LB35 Door Bi-Part Opening with Side Screens LB35 111NA - LB35 Door Single Slide Opening with Side Screen plus Fanlight LB35 212NA - LB35 Door Bi-Part Opening with Side Screens plus Fanlight
Product descriptionUsed in all solutions with external sliding doors and insulating glass. Ideal for internal applications, like office partition walls, malls and airport separation areas. It perfectly suits the best architectural and design solutions. Single or double leaf sliding doors, with optional fixed side leaves. It can be installed on a transom or on a built-in self-supporting transom.
Technical purpose of productIdeal for internal applications, like office partition walls, malls and airport separation areas.
Manufacturing or service provision descriptionFor the production of windows and doors, the company purchases materials such as glass, aluminum profiles and various accessories and proceeds with the cutting of the profiles to size at the production site. Subsequently, manual assembly is carried out and finally the product is packaged ready for shipping.
Material propertiesConversion factor to mass: 0.04 LCA results per 1 kg Area density: 24.01 kg/m2 Thickness: 0.035 m
Production siteLABEL spa Italy Parma 43126 Via Umberto Ilariuzzi, 17/A
UN CPC code4212. Doors, windows and their frames and thresholds for doors, of iron, steel or aluminium
Geographical scopeGlobal

Content declaration

Content declaration of multiple productsThe composition of the average product and the least recycled content are reported.
Hazardous and toxic substancesThe product does not contain any substances from the SVHC candidate list in concentrations exceeding 0.1% of its weight.
Product content
Content nameWeight, kgPost-consumer recycled material, weight-% of productBiogenic material, weight-% of productBiogenic material1, kg C/declared unit
Aluminium3.66000
Glass19.42000
Steel0.1000
EPDM0.74000
Plastic0.09000
Total24.01000
Note 11 kg biogenic carbon is equivalent to 44/12 kg of CO2
Packaging materials
Material nameWeight, kgWeight-% (versus the product)Biogenic material1, kg C/declared unit
Cardboard1.2600
wood9.6700
Nylon0.400
LDPE0.0900
Total11.4200
Note 11 kg biogenic carbon is equivalent to 44/12 kg of CO2

LCA information

EPD based on declared or functional unitDeclared unit
Declared unit and reference flowDoor profile system Area: 1 m2
Conversion factor to mass0.04
Are infrastructure or capital goods included in any upstream, core or downstream processes?
Detailed description of infrastructure and capital goods

Infrastructure/capital goods (transport and energy infrastructure) are included in generic LCI dataset used for upstream and downstream processes and contributes less than 5% to the cradle-to-gate results of any of the environmental impact indicators.

Datasources used for this EPDecoinvent database (general) ecoinvent 3.9.1 database
LCA SoftwareOpenLCA OpenLCA 1.9
Version of the EN 15804 reference packageEF Reference Package 3.1
Technology description including background systemThe system meets the safety requirements provided for by Standard EN 16005. Certified in a Notified Laboratory in accordance with the provisions of Standard EN 16361. Profiles made of extruded EN AW-6060 aluminium alloy in accordance with standard EN 573-1 with T6 finishing designation in accordance with standard EN 515. Dimensional tolerances and thicknesses in accordance with Standard EN 755-9. Gaskets made of extruded black EPDM mix in accordance with Standards EN 12365-1 and DIN 7863-1. L2 Class cut length tolerances in accordance with Standard ISO 3302. Glazing available with safety laminated glass, complying with Standard EN 14449 and having a nominal thickness of 44.2 or 55.2. Insulating Glass, complying with Standard EN 1279-5 and having a nominal thickness of 28 mm. Monolithic glasses, thermally toughened in accordance with standard EN 12150-2, can be used for 8 and 10mm thicknesses. Glasses can also be laminated inside the insulating glass, without exceeding the total thickness. Surface Protection Finishing of aluminium profiles made in accordance with the European Technical Directives Qualanod EURAS-EWAA for finishing with anodising treatment or with Thermosetting Powder Painting Treatment in accordance with the Qualicoat quality mark Directives.
Scrap (recycled material) inputs contribution levelLess than 10% of the GWP-GHG results in modules A1-A3 come from scrap inputs
Electricity data
Electricity used in the manufacturing process in A3
Type of electricity mixResidual electricity mix on the market
Energy sourcesHydro0%
Wind0.43%
Solar6.21%
Biomass0.63%
Geothermal0%
Waste0%
Nuclear4.4%
Natural gas58.22%
Coal22.72%
Oil3.76%
Peat0.05%
Other3.57%
GWP-GHG intensity (kg CO2 eq./kWh)0.67 kg CO2 eq./kWh

System boundary

Description of the system boundarya) Cradle to gate with modules C1-C4 and module D (A1-A3 + C + D).
Excluded modulesNo, there is no excluded module, or there are no excluded modules

Declared modules

Product stageConstruction process stageUse stageEnd of life stageBeyond product life cycle
Raw material supplyTransportManufacturingTransport to siteConstruction installationUseMaintenanceRepairReplacementRefurbishmentOperational energy useOperational water useDe-construction demolitionTransportWaste processingDisposalReuse-Recovery-Recycling-potential
ModuleA1A2A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
Modules declaredXXXNDNDNDNDNDNDNDNDNDXXXXX
GeographyGlobalGlobalItalyN/AN/AN/AN/AN/AN/AN/AN/AN/AGlobalGlobalGlobalGlobalGlobal
Share of specific data19.1%--------------
Variation - products43.1%--------------
Variation - sites0%--------------

Default scenario

Name of the default scenarioEnd of Life
Description of the default scenarioIn the absence of data that can be used to justify a particular End of Life scenario, the default scenario for metal windows and doorstet is used (Annex B - EN 17213:2020)

Module C: End-of-life

Explanatory name of the default scenario in module CRecovery/Disposal
Brief description of the default scenario in module Cglass 70% for disposal, non-glass materials 5% for disposal
Description of the default scenario in module CThe product undergoes a manual demolition process (C1). Regarding the treatment of waste generated during demolition, it can be transported for recovery (C2), subsequently undergoing treatments such as grinding and sorting (C3), or for disposal (C4): non-glass materials from the demolished product are destined 95% for waste recovery treatment and 5% for disposal; whereas glass materials are sent 30% for treatment and 70% for disposal.

Module D: Beyond product life cycle

Explanatory name of the default scenario in module DEnd-of-life benefit
Brief description of the default scenario in module Dcalculated as the total amount of materials sent for recovery: metals and glass
Description of the default scenario in module DThe end-of-life benefits have been calculated as the total amount of materials sent for recovery, such as metals and glass, and for energy recovery, such as plastic.

Environmental performance

The estimated impact results are only relative statements, which do not indicate the endpoints of the impact categories, exceeding threshold values, safety margins and/or risks.

Mandatory environmental performance indicators according to EN 15804

Impact categoryIndicatorUnitA1-A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
Climate change - totalGWP-totalkg CO2 eq.1.21E+2NDNDNDNDNDNDNDNDND0.00E+02.29E-11.59E+01.53E-1-2.61E+1
Climate change - fossilGWP-fossilkg CO2 eq.1.21E+2NDNDNDNDNDNDNDNDND0.00E+02.29E-11.59E+01.53E-1-2.54E+1
Climate change - biogenicGWP-biogenickg CO2 eq.3.28E-1NDNDNDNDNDNDNDNDND0.00E+06.57E-53.96E-39.31E-5-1.02E-1
Climate change - land use and land-use changeGWP-luluckg CO2 eq.8.61E-4NDNDNDNDNDNDNDNDND0.00E+08.60E-71.30E-52.14E-6-2.50E-5
Ozone depletionODPkg CFC-11 eq.8.92E-7NDNDNDNDNDNDNDNDND0.00E+03.62E-91.28E-84.05E-9-7.34E-7
AcidificationAPmol H+ eq.9.98E-1NDNDNDNDNDNDNDNDND0.00E+01.01E-34.36E-31.07E-3-1.61E-1
Eutrophication aquatic freshwaterEP-freshwaterkg P eq.5.01E-2NDNDNDNDNDNDNDNDND0.00E+01.86E-52.69E-41.73E-5-1.43E-2
Eutrophication aquatic marineEP-marinekg N eq.1.51E-1NDNDNDNDNDNDNDNDND0.00E+03.60E-47.84E-43.98E-4-2.09E-2
Eutrophication terrestrialEP-terrestrialmol N eq.1.52E+0NDNDNDNDNDNDNDNDND0.00E+03.95E-38.71E-34.35E-3-2.05E-1
Photochemical ozone formationPOCPkg NMVOC eq.4.54E-1NDNDNDNDNDNDNDNDND0.00E+01.36E-32.87E-31.50E-3-9.01E-2
Depletion of abiotic resources - minerals and metalsADP-minerals&metals1, 2kg Sb eq.1.59E-4NDNDNDNDNDNDNDNDND0.00E+07.55E-72.39E-53.14E-7-5.44E-5
Depletion of abiotic resources - fossil fuelsADP-fossil1MJ, net calorific value1.43E+3NDNDNDNDNDNDNDNDND0.00E+03.26E+08.03E+03.44E+0-4.32E+2
Water useWDP1m3 world eq. deprived2.07E+1NDNDNDNDNDNDNDNDND0.00E+01.54E-21.55E-11.47E-2-4.92E+1
AcronymsGWP-fossil = Global Warming Potential fossil fuels; GWP-biogenic = Global Warming Potential biogenic; GWP-luluc = Global Warming Potential land use and land use change; ODP = Depletion potential of the stratospheric ozone layer; AP = Acidification potential, Accumulated Exceedance; EP-freshwater = Eutrophication potential, fraction of nutrients reaching freshwater end compartment; EP-marine = Eutrophication potential, fraction of nutrients reaching marine end compartment; EP-terrestrial = Eutrophication potential, Accumulated Exceedance; POCP = Formation potential of tropospheric ozone; ADP-minerals&metals = Abiotic depletion potential for non-fossil resources; ADP-fossil = Abiotic depletion for fossil resources potential; WDP = Water (user) deprivation potential, deprivation-weighted water consumption
General disclaimerThe results of the end-of-life stage (modules C1-C4) should be considered when using the results of the product stage (modules A1-A3/A1-A5 for services).
Disclaimer 1The results of this environmental impact indicator shall be used with care as the uncertainties of these results are high or as there is limited experience with the indicator
Disclaimer 2The results of the impact categories abiotic depletion of minerals and metals may be highly uncertain in LCAs that include capital goods/infrastructure in generic datasets, in case infrastructure/capital goods contribute greatly to the total results. This is because the LCI data of infrastructure/capital goods used to quantify these indicators in currently available generic datasets sometimes lack temporal, technological and geographical representativeness. Caution should be exercised when using the results of these indicators for decision-making purposes.

Additional mandatory environmental performance indicators

Impact categoryIndicatorUnitA1-A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
Climate change - GWP-GHGGWP-GHG1kg CO2 eq.1.21E+2NDNDNDNDNDNDNDNDND0.00E+02.29E-11.59E+01.53E-1-2.61E+1
AcronymsGWP-GHG = Global warming potential greenhouse gas.
General disclaimerThe results of the end-of-life stage (modules C1-C4) should be considered when using the results of the product stage (modules A1-A3/A1-A5 for services).
Disclaimer 1The GWP-GHG indicator is termed GWP-IOBC/GHG in the ILCD+EPD+ data format. The indicator accounts for all greenhouse gases except biogenic carbon dioxide uptake and emissions and biogenic carbon stored in the product. As such, the indicator is identical to GWP-total except that the CF for biogenic CO2 is set to zero.

Additional voluntary environmental performance indicators according to EN 15804

Impact categoryIndicatorUnitA1-A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
Particulate matter emissionsPMDisease incidence5.89E-6NDNDNDNDNDNDNDNDND0.00E+01.87E-87.02E-82.24E-8-1.87E-6
Ionizing radiation - human healthIRP1kBq U235 eq.6.01E+0NDNDNDNDNDNDNDNDND0.00E+02.75E-36.36E-25.03E-3-6.70E+0
Eco-toxicity - freshwaterETP-fw2, 3CTUe3.10E+2NDNDNDNDNDNDNDNDND0.00E+01.72E+05.37E+01.59E+0-9.60E+1
Human toxicity - cancer effectsHTP-c2, 3CTUh9.89E-8NDNDNDNDNDNDNDNDND0.00E+01.04E-106.69E-107.38E-11-7.45E-8
Human toxicity - non-cancer effectsHTP-nc2, 3CTUh1.63E-6NDNDNDNDNDNDNDNDND0.00E+02.09E-92.75E-81.01E-9-7.44E-7
Land-use related impacts/soil qualitySQP2, 3Dimensionless2.70E+3NDNDNDNDNDNDNDNDND0.00E+01.93E+07.10E+06.08E+0-2.10E+1
AcronymsPM = Potential incidence of disease due to particulate matter emissions; IRP = Potential human exposure efficiency relative to U235; ETP-fw = Potential comparative toxic unit for ecosystems; HTP-c = Potential comparative toxic unit for humans; HTP-nc = Potential comparative toxic unit for humans; SQP = Potential soil quality index.
General disclaimerThe results of the end-of-life stage (modules C1-C4) should be considered when using the results of the product stage (modules A1-A3/A1-A5 for services).
Disclaimer 1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
Disclaimer 2The results of this environmental impact indicator shall be used with care as the uncertainties of these results are high or as there is limited experience with the indicator.
Disclaimer 3The results of the impact categories land use, human toxicity (cancer), human toxicity, noncancer and ecotoxicity (freshwater) may be highly uncertain in LCAs that include capital goods/infrastructure in generic datasets, in case infrastructure/capital goods contribute greatly to the total results. This is because the LCI data of infrastructure/capital goods used to quantify these indicators in currently available generic datasets sometimes lack temporal, technological and geographical representativeness. Caution should be exercised when using the results of these indicators for decision-making purposes.

Resource use indicators according to EN 15804

IndicatorUnitA1-A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
PEREMJ, net calorific value5.54E+2NDNDNDNDNDNDNDNDND0.00E+04.12E-28.96E-15.28E-2-1.53E+2
PERMMJ, net calorific value8.73E-1NDNDNDNDNDNDNDNDND0.00E+00.00E+00.00E+00.00E+00.00E+0
PERTMJ, net calorific value5.55E+2NDNDNDNDNDNDNDNDND0.00E+04.12E-28.96E-15.28E-2-1.53E+2
PENREMJ, net calorific value1.05E+3NDNDNDNDNDNDNDNDND0.00E+03.26E+08.03E+03.44E+0-4.32E+2
PENRMMJ, net calorific value5.12E+1NDNDNDNDNDNDNDNDND0.00E+00.00E+00.00E+00.00E+00.00E+0
PENRTMJ, net calorific value1.10E+3NDNDNDNDNDNDNDNDND0.00E+03.26E+08.03E+03.44E+0-4.32E+2
SMkg8.11E-1NDNDNDNDNDNDNDNDND0.00E+00.00E+00.00E+00.00E+00.00E+0
RSFMJ, net calorific value0.00E+0NDNDNDNDNDNDNDNDND0.00E+00.00E+00.00E+00.00E+00.00E+0
NRSFMJ, net calorific value0.00E+0NDNDNDNDNDNDNDNDND0.00E+00.00E+00.00E+00.00E+00.00E+0
FWm34.53E-1NDNDNDNDNDNDNDNDND0.00E+03.96E-44.28E-33.10E-3-1.09E+0
AcronymsPERE = Use of renewable primary energy excluding renewable primary energy resources used as raw materials; PERM = Use of renewable primary energy resources used as raw materials; PERT = Total use of renewable primary energy resources; PENRE = Use of non-renewable primary energy excluding non-renewable primary energy resources used as raw materials; PENRM = Use of non-renewable primary energy resources used as raw materials; PENRT = Total use of non-renewable primary energy re-sources; SM = Use of secondary material; RSF = Use of renewable secondary fuels; NRSF = Use of non-renewable secondary fuels; FW = Use of net fresh water.
General disclaimerThe results of the end-of-life stage (modules C1-C4) should be considered when using the results of the product stage (modules A1-A3/A1-A5 for services).

Waste indicators according to EN 15804

IndicatorUnitA1-A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
HWDkg1.41E+1NDNDNDNDNDNDNDNDND0.00E+03.71E-38.03E-22.81E-3-5.97E+0
NHWDkg1.82E+1NDNDNDNDNDNDNDNDND0.00E+01.58E-16.70E-11.85E+1-7.37E+0
RWDkg2.20E-2NDNDNDNDNDNDNDNDND0.00E+06.55E-71.62E-51.24E-6-1.78E-3
AcronymsHWD = Hazardous waste disposed; NHWD = Non-hazardous waste disposed; RWD = Radioactive waste disposed.
General disclaimerThe results of the end-of-life stage (modules C1-C4) should be considered when using the results of the product stage (modules A1-A3/A1-A5 for services).

Output flow indicators according to EN 15804

IndicatorUnitA1-A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
CRUkg0.00E+0NDNDNDNDNDNDNDNDND0.00E+00.00E+00.00E+00.00E+00.00E+0
MFRkg1.82E+0NDNDNDNDNDNDNDNDND0.00E+00.00E+00.00E+00.00E+00.00E+0
MERkg2.01E-1NDNDNDNDNDNDNDNDND0.00E+00.00E+00.00E+00.00E+00.00E+0
EEEMJ, net calorific value1.12E-1NDNDNDNDNDNDNDNDND0.00E+00.00E+00.00E+00.00E+00.00E+0
EETMJ, net calorific value1.32E+0NDNDNDNDNDNDNDNDND0.00E+00.00E+00.00E+00.00E+00.00E+0
AcronymsCRU = Components for re-use; MFR = Materials for recycling; MER = Materials for energy recovery; EEE = Exported electrical energy; EET = Exported thermal energy.
General disclaimerThe results of the end-of-life stage (modules C1-C4) should be considered when using the results of the product stage (modules A1-A3/A1-A5 for services).

References

General Programme Instructions of the International EPD® System. Version 4.0.

PCR 2019:14. CONSTRUCTION PRODUCTS. Version 1.3.4

c-PCR-007, version 1.0.0 WINDOWS AND DOORS (EN 17213:2020)

EN 17213:2020 Windows and doors — Environmental Product Declarations — Product category rules for windows and pedestrian doorsets

Version history

Product codes and thickness have been added.